Specifications for Micro Dri & Micro Dri II Air Dryer Systems
(To use the hide/show rows
feature on this page you need your JavaScript turned on)
Micro Dri 50 | Micro Dri 200 | Micro Dri 600 |
Micro Dri 12001 | Micro Dri 30001 | Micro Dri 2501 |
Micro Dri II 50 | Micro Dri II 200 | Micro Dri II 600 |
Model |
Dimensions |
Net Weight |
Compressor |
Power* |
Output (SCFD) |
Humidity (@70°F) |
Dewpoint |
Output Pressure |
Standard Alarms |
---|
Micro Dri 50 |
24"W x 10"D x 17"H (61cm x 25cm x 43cm) |
73 lbs (33 kg) |
1/16 HP |
115 VAC 60 Hz |
50 |
2%RH |
-40°C (-40°F) |
0-15 or 0-2 PSIG |
Low Pressure, Humidity, Hi-Low Pressure, Power, Compressor Failure |
Micro Dri 200 |
24"W x 10"D x 17"H (61cm x 25cm x 43cm) |
81 lbs (36 kg) |
1/86 HP |
115 VAC 60 Hz |
225 |
2%RH |
-40°C (-40°F) |
0-15 or 0-2 PSIG |
Low Pressure, Humidity, Hi-Low Pressure, Power, Compressor Failure |
Micro Dri 600 |
24"W x 10"D x 17"H (61cm x 25cm x 43cm) |
81 lbs (36 kg) |
1/6 HP |
115 VAC 60 Hz |
600 |
2%RH |
-40°C (-40°F) |
0-15 or 0-2 PSIG |
Low Pressure, Humidity, Hi-Low Pressure, Power, Compressor Failure |
Micro Dri 12001 |
28"W x 13"D x 17"H (71cm x 34cm x 43cm) |
115 lbs (52 kg) |
1/3 HP |
115 VAC 60 Hz |
1200 |
2%RH |
-40°C (-40°F) |
0-15 PSIG |
Low Pressure, Excess Run Time, High Humidity, Power |
Micro Dri 30001 |
60"W x 15"D x 24"H (152cm x 38cm x 61cm) |
325 lbs (147 kg) |
** |
115 VAC 60 Hz |
3000 |
2%RH |
-40°C (-40°F) |
7-9.25 Inches WG |
Low Pressure, High Humidity |
Micro Dri 2501 |
48"W x 18"D x 21"H (122cm x 47cm x 53cm) |
185 lbs (84 kg) |
1/3 HP |
115 VAC 60 Hz |
250 |
0.010%RH |
-70°C (-56°F) |
0-2 PSIG |
Hi-Low Pressure |
Micro Dri II 50 |
18"W x 11"D x 17"H (46cm x 28cm x 43cm) |
40 lbs (18 kg) |
1/16 HP |
115 VAC 60 Hz |
50 |
2%RH |
-40°C (-40°F) |
0-15 or 0-2 PSIG |
Low Pressure |
Micro Dri II 200 |
18"W x 11"D x 17"H (46cm x 28cm x 43cm) |
48 lbs (21 kg) |
1/8 HP |
115 VAC 60 Hz |
225 |
2%RH |
-40°C (-40°F) |
0-15 or 0-2 PSIG |
Low Pressure |
Micro Dri II 600 |
18"W x 11"D x 17"H (46cm x 28cm x 43cm) |
48 lbs (21 kg) |
1/6 HP |
115 VAC 60 Hz |
600 |
2%RH |
-40°C (-40°F) |
0-15 or 0-2 PSIG |
Low Pressure |
*220 VAC 50 Hz 1 Phase Available1 - By quotation only **Self Regulation Blower |